Inverter Heat Pump
1.5 HP
Indoor Unit: 295 mm(H) x 880 mm(W) x 309 mm(D)
Outdoor Unit: 550 mm(H) x 800 mm(W) x 285 mm(D)
R410A
Grade 1 Energy Label
Recently Viewed

Feature


More


Easy Cleaning  Design
ECONO COOL
Indoor Unit Temperature Display
Sleep Mode
Outdoor unit only 55cm high
Human Sense MOVE EYE
Direct/Indirect Flow
Reheat Dehumidification
Vertical(14 Modes) / Horizontal Auto Swing (10 Modes)
Aluminium Magnesium Alloy Curved Front Panel
Energy Efficiency Grade 1 (Cooling / Heating)
Computerized Dehumidification
Inverter Control
Heat Pump
Self Diagnosis
24 Hour Pre-set On/Off
LCD Display Remote Controller
Noise-Reducing Design
Electric Circuit Protection
Cooling Capacity 3.60kW

Specifications

Model Indoor Unit MSZ-PAH12VA-H1
Model Outdoor Unit MUZ-AH12VA-H1
Color Indoor Unit
Operation Mode Cooling / Heating
Cooling / Heating Capacity Rated kW 3.60 / 4.50
Cooling / Heating Capacity Rated BTU/h 12,283 / 15,354
Cooling / Heating Capacity Min-Max kW 0.60-4.30 / 0.60-5.80
Cooling / Heating Capacity Min-Max BTU/h 2,047-14,672 / 2,047-19,790
Power Consumption Rated kW 0.93 / 1.05
Power Consumption Min-Max kW 0.12-1.43 / 0.13-1.58
Operating Current A 4.50 / 5.00
Air Circulation m³/min. 10.73 / 11.30
C.O.P. 3.89 / 4.29
Dehumidifying Capacity I/h 1.19 / 1.19
Noise Level Indoor Unit (Si)/Lo-Hi dB(A) 23-40 / 22-39
Noise Level Outdoor Unit dB(A) 46 / 49
Dimension (H x W x D) Indoor Unit mm 295 × 880 × 309
Dimension (H x W x D) Outdoor Unit mm 550 × 800 × 285
Weight Indoor Unit kg 14
Weight Outdoor Unit kg 33
Refrigerant Pipe Diameter Liquid / Gas mm Ø6.35 / Ø9.52
Max. Piping Dimension Height Difference / Length m 8 / 12
Voltage V 220
Phase / Frequency Single / 50Hz
Refrigerant R410A
Energy Efficiency Grade 1
Optional Parts
Model Indoor Unit MSZ-PAH12VA-H1
Model Outdoor Unit MUZ-AH12VA-H1
Color Indoor Unit
Operation Mode Cooling / Heating
Cooling / Heating Capacity Rated kW 3.60 / 4.50
Cooling / Heating Capacity Rated BTU/h 12,283 / 15,354
Cooling / Heating Capacity Min-Max kW 0.60-4.30 / 0.60-5.80
Cooling / Heating Capacity Min-Max BTU/h 2,047-14,672 / 2,047-19,790
Power Consumption Rated kW 0.93 / 1.05
Power Consumption Min-Max kW 0.12-1.43 / 0.13-1.58
Operating Current A 4.50 / 5.00
Air Circulation m³/min. 10.73 / 11.30
C.O.P. 3.89 / 4.29
Dehumidifying Capacity I/h 1.19 / 1.19
Noise Level Indoor Unit (Si)/Lo-Hi dB(A) 23-40 / 22-39
Noise Level Outdoor Unit dB(A) 46 / 49
Dimension (H x W x D) Indoor Unit mm 295 × 880 × 309
Dimension (H x W x D) Outdoor Unit mm 550 × 800 × 285
Weight Indoor Unit kg 14
Weight Outdoor Unit kg 33
Refrigerant Pipe Diameter Liquid / Gas mm Ø6.35 / Ø9.52
Max. Piping Dimension Height Difference / Length m 8 / 12
Voltage V 220
Phase / Frequency Single / 50Hz
Refrigerant R410A
Energy Efficiency Grade 1
Optional Parts
Remarks
1.The product specifications are provided by factories of Mitsubishi Electric.
2.Before purchase and installation, the space and position needed for installation should be confirmed by qualified engineers.
3.Designs and specifications are subject to change without prior notice.
4.There may be some differences between the products’ sizes stated in this page and those of the actual products.

Others

Download
Part No.:
Accessories
Reserve Accessories Now
Download
MSZ-PAH09VA-H1 / MSZ-PAH12VA-H1
Outlines and dimensions
Residential Use
Technical Book
MSZ-PAH09VA-H1 / MSZ-PAH12VA-H1
Instruction Book
Product Filter
Comparing 0 Products
Clear All Products
Facebook Messenger